Your Position:Home > Product > Dc-link > 其他定制类

DLE系列

Update:2015/10/14 18:03:37      View:6081
  • Type   DLE系列
  • Description

    英文描述

Introduction

1,Side shell products , the bolt installation;

2, voltage 800--12000VDC; capacity 50--30000uf;

3, ultra low ESL, ESR, high frequency characteristics;

4, for the bus filtering, storage, feedback;

Technical data book download address



Typical polypropylene dielectric characteristics




General Remarks                                                            

Rated capacitance CN

Capacitance value rated at20°C/ 50 Hz.

Rated AC voltage UN

Maximum operating peak recurrent voltage of either polarity of a reversing type waveform for which the capacitor has been designed.

Rated DC voltage UNDC

Maximum operating peak voltage of either polarity but of a non-reversing type waveform,for which the capacitor has been designed,for continuous operation.

Ripple voltage Ur

Maximum value of the peak-to-peak alternating component of the unidirectional voltage. This value is stated only for DC-capacitors. The peak-to-peak value of AC- and AC/DC-types is always 2 × UNAC.

Non-recurrent surge voltage Us

Peak voltage induced by a switching or any other disturbance of the system which is allowed for a limited number of times and duration.

- Maximum duration: 50 ms / pulse. Maximum number of occurrences: 1000 (during load)

Insulation voltage Ui

Rms rated value of the insulation voltage of capacitive elements and terminals to case or earth.

rms voltage Urms

Root mean square of max. permissible value of sinusoidal AC voltage in continuous operation. In power electronics, the RMS voltage is usually not the rated voltage value of the capacitor.

Maximum current Imax

Maximum rms current for continuous operation.

Maximum rate of voltage rise (du/dt)max

Maximum permissible repetitive rate of voltage rise of the operational voltage.

Maximum peak current Î

Maximum permissible repetitive current amplitude during continuous operation.

Maximum peak current (Î) and maximum rate of voltage rise (du/dt)max on a capacitor are related as follows:          Î = C × (du/dt)max

Maximum non-repetitive rate of voltage rise (du/dt)S

Peak rate of voltage rise that may occur non-repetitively and briefly in the event of a fault.

Maximum surge current Î s

Admissible peak current induced by a switching or any other disturbance of the system which is allowed for a limited number of times (1000 times) and duration (50 ms / pulse).

Îs = C × (du/dt)s

Ambient temperature ΘA

Temperature of the surrounding air, measured at10 cmdistance and 2/3 of the case height of the capacitor.

Lowest operating temperatureΘmin

Lowest permitted ambient temperature at which a capacitor may be energized.

Maximum operating temperatureΘmax

Highest permitted capacitor temperature during operation, i.e. temperature at the hottest point of the case. It is, however, not sufficient to monitor the surface temperature. Life-span and safe operation crucially depend

on the observance of the hotspot temperature.

Hot-spot temperatureΘhs

Temperature zone inside of the capacitor at hottest spot. It has to be noted that,depending on the thermal power dissipation generated inside the capacitor,there is always a temperature difference between hotspot and surface.  As the hotspot is usually not accessible for measurement, Θhs must be calculated based on

the data stated in the catalogue or data sheet:

Θhs =ΘA+ Irms2x ESR x Rth

Important: No thermal dissipation losses are admissible when operating a capacitor at an ambient temperature equal to the upper category temperature,i.e. Irms and Q shall be zero (operation at pure DC voltage) !

Dielectric dissipation factor tanδ0

Constant dissipation factor of the dielectric material for all capacitors at their rated frequency.The typical loss factor of pp film is tanδ0 = 2 x 10-4.

Dissipation factor tanδ

Loss factor of the capacitor at sinusoidal ac voltage and applied frequency.It is calculated as follows:   tanδ (ƒ) = tanδ0 + RS x 2πƒ x CN

Series resistance Rs

The sum of all Ohmic resistances occurring inside the capacitor.

Equivalent Series Resistance ESR

Represents the sum of all loss resistances occurring in the capacitor. It depends on frequency and is essential for the calculation of the capacitor’s total power losses.

ESR = RS +tanδ0 /(2πƒ x CN)

Thermal resistance Rth

The thermal resistance indicates by how many degrees the capacitor temperature at the hot spot rises in relation to the dissipation losses.

Maximum power loss Pmax

Maximum permissible power dissipation for the capacitor’s operation.

Pmax =(Θhs – ΘA)/Rth

Self inductance Ls

The sum of all inductive elements which are contained in a capacitor.

Resonance frequency fr

The lowest frequency at which the impedance of the capacitor becomes minimum.

Rated energy contents WN

Energy stored in the capacitor when charged at rated voltage.

WN =1/2CN× UN²

Clearance in air L

The shortest distance between conducting parts of the terminals or between terminals and case. In this catalogue, we state only the shorter.

Creepage distance K

The shortest distance along an insulated surface between conducting parts of the terminals or between terminals and case. In this catalogue, again we state only the shorter.

 DC Capacitor Expected life and Failure rate                                                

DC capacitor Lifetime statements vs. Failure rate

In the lifetime expectancy graphic, statements for more than 200,000 hrs are cut off as they are technically unreasonable. For higher hotspot temperatures, no statements are made regarding operation at overvoltage: the simultaneous operation at limit values results in unpredictable conditions. Here, the statement of a FIT rate - that reflects the growing risk at such extreme conditions - would be of far better use.

DC capacitor Lifetime Expectancy Graphs



DC capacitor FIT rates (Failures In Time):

By reflecting the probability (in other words: risk) of failures during the operating period under selected operating conditions, it provides information on what effects to expect when de-rating (or over-loading) a capacitor. The failure probability of a component is a statistical value which is described by a log-normal distribution:

N = No × e¯λt

N = number of functional components after period t

No = total number of components at time t = 0

λ = failure rate

λ is the failure rate, which alternatively is also stated as the so-called FIT-rate (FIT = Failures In Time = λ×109). Service cycles may be calculated based on the so-called MTBF value (mean time between failures): MTBF = 1/λ. The failure rate is very closely linked with the operating temperature and the operating voltage applied to the capacitor. As standard, our FIT rates are related to a realistic (from a technical and statistical point of view) operating interval of t=100,000 hours, assuming a capacitor hotspot temperature of70°C. Hotspot is the only reliable criterion in relation to the capacitor’s temperature stress. The outside temperatures may be comparably low, however with high electrical stress the temperature rise in the capacitor may be substantial due to the power dissipation losses produced inside. This could result in the same temperature stress as a generally high ambient temperature.

The simultaneous operation of capacitors at highest permissible voltage and operating temperature should be avoided; otherwise, failure rates may increase beyond reasonable technical reliability.

In fact, a FIT rate of 50 would mean, for example: “If 10,000 capacitors are operated simultaneously for 100,000 hours at rated voltage and with a hotspot temperature of no more than70°C, then out of this batch no more than 50 pcs may fail during the entire period.” Any period during which the hotspot temperature is lower than70°C, or the voltage is less than rated voltage, will contribute to a reduction of the 50 FIT.

After the reference interval, the capacitors will continue operating; however the probability of failures may change. It shall be noted that the statements on FIT rates are based mainly on long-year empirical experience; at ADSO, we are conducting numerous and regular reliability tests to verify and back up our empirical knowledge. However dedicated studies designed to prove FIT rates would require the test of thousands of capacitors, over hundreds of thousands of hours, which is technically and commercially impossible. Even the use of statistical methods and accelerated ageing factors encounters physical and chemical limits.

Hence lifetime formulas such as

Lifetime (U) = LN x (Urated/Uworking)8  and   Lifetime (Θ) = LN x 2(Θrated-Θworking)/7

should not be used to calculate absolute figures of expected lifetime. These rules and formulas are mainly designed to give an approximate feeling for the importance of voltage and temperature.

All standard items of ADSO are designed and dimensioned to comply with their FIT rate as stated in the catalogue or special data sheet. FIT rate statements related to longer reference intervals can be made on request. Further, capacitor designs can be adapted on request to achieve lower FIT at the intended operating conditions.

Based on our current state of knowledge derived from test data and experience, we quote the following FIT rates for our standard products at the a.m. conditions:

DC capacitor FIT rates Quota Graphs



                                                  General Safety Advices

Cautions and warnings

_ In case of dents of more than1 mmdepth or any other mechanical damage, capacitors must

not be used at all.

_ Check tightness of the connections/terminals periodically.

_ The energy stored in capacitors may be lethal. To prevent any chance of shock, discharge and short-circuit the capacitor before handling.

_ Failure to follow cautions may result, worst case, in premature failures, bursting and fire.

_ ADSO is not responsible for any kind of possible damages to persons or things due to improper installation and application of capacitors for power electronics.

Safety

_ Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage may result from bursting of the capacitor or from expulsion of oil or melted  material due to mechanical disruption of the capacitor.

_ Ensure good, effective grounding for capacitor enclosures.

_ Observe appropriate safety precautions during operation (self-recharging phenomena and the high energy contained in capacitors).

_ Handle capacitors carefully, because they may still be charged even after disconnection.

_ The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized.

_ Follow good engineering practice.

Thermal load

After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at extreme service conditions.

Mechanical protection

The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided.

Storage and operating conditions

Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas,

acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning

especially of the terminals is required to avoid conductive path between phases and/or phases

and ground.

The maximum storage temperature is85 °C.

Service life expectancy

Electrical components do not have an unlimited service life expectancy; this applies to self-healing capacitors, too. The maximum service life expectancy may vary depending on the application the capacitor is used in.

The following applies to all products named in this publication:

1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, ADSO is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an ADSO product with the properties described in the product specification is suitable for use in a particular customer application.

2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component.

3. The warnings, cautions and product-specific notes must be observed.

4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet. Should you have any more detailed questions, please contact our sales offices.

5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available.